  • +50°Сmax
  • 240W/sq.m.
  • 150 cmwidth
  • 20 cmsection
  • 220 V50 Hz

other product variants

Power, W/linear.

characteristics

Power, W/linear. 360
Max. heating temperature,°С 50
Collection Infrared floor under the tile and screed
Type Textile, covered, solid.
Application of the carbon layer By bands
Operating voltage, V 220
Efficiency, % 98

characteristics

Power, W/m2. 360
Max. heating temperature,°С 50
Collection Infrared floor under the tile and screed
Type Textile, covered, solid.
Application of the carbon layer By bands
Operating voltage, V 220
Efficiency, % 98

description

Heating Textile is a protected film of the fourth generation of an innovative structure. The basis of the film is a grid treated with electroconductive carbon. Fiberglass yarn and polymer thread are interwoven into the mesh. This structure provides not only high strength and reliability, but also increased efficiency, as well as lower power consumption. The maximum power of the film is 216 W / m. allows you to effectively heat rooms with large heat losses and use a film in heating appliances. The current-carrying copper thread is very thin (0.27 mm in diameter) and has a continuous path through the entire length of the fabric. The patented method allows to increase the number of woven metallic conductor threads into carbon fabric, thanks to this, the total area of ​​the conductor is 2.5 mm2. Copper conductor thread perfectly integrates with carbon fabric, using textile processes. The class of films Heating Textiles from TM Heat Plus are especially strong and highly efficient infrared films of the fourth generation, which significantly exceed, in all respects, other classes of Heat Plus films and analogues on the market of infrared films. The film in its structure has more layers and is technologically more durable and reliable. Due to the multilayeredness and new production technology, based on the intertwining of yarn from fiberglass and polymer yarn, it was possible to significantly improve the safety parameters of use. Due to good thermal conductivity and heat resistance, Heating Textile is ideally suited for use as a heating medium. At the same time, the fibers provide a high degree of flexibility, and the heating circuits can be applied in different geometries on the carrier material. Due to the special structure, overheating and the effect of local heat blocking on the film itself are minimized. In simple words, placing furniture or other objects on a film does not do any harm to it. Moreover, this film is designed for work in anti-icing and snow melting systems. It can be mounted and used under paving slabs, concrete, or asphalt. The width of the film Textile is 90 cm. Unlike the Sauna and Premium films, this film is not divided into two strips. The cut lines of the film are widthwise every 20 cm, but technologically it is possible to cut them on any stripes and even obliquely. High power, dimensional flexibility, film flexibility, efficiency and economy, increased strength and reliability of the film will allow it to be used for rooms with a high heat loss rate, in heating appliances, mobile heating and other technological solutions that can not be solved with films of previous generations (Standard, Premium, Sauna). The most important part in the construction of the infrared film is the place of contact between the current carrying copper bus and the carbon heating layer. Reliable contact is provided by a silver tire, which completely covers the area of the copper conductor and ensures the absence of an air gap. Due to the high quality of the copper conductor, the lowest contact resistance (0.1 Ω) is reached, which minimizes the electrical losses at the contacts.

characteristics

main

Max power 360 W/m2 ± 10%
Working temperature 40-50 t, °С
Efficiency, % 98
unit of measurement linear meter
Cutting is a multiple of 20 cm in length
Width 1.5 m
Film thickness 2 mm
In a roll 30 m
Roll weight 50 kg
Type of film Textile, covered, solid.
Type of heating Basic, additional
Guarantee 15 years
Lifetime 50 years
Composition Textile fibers, impregnated with carbon with interwoven tinned copper wire, polyethylene terephthalate (PET), urethane.

others

Collection Infrared floor under the tile and screed
Product of South Korea
Manufacturer HEAT PLUS
Guarantee 15 yeaes
Vendor code 310000

film structure heat plus

#

Features of heating textile heat plus

The current-carrying copper thread is very thin (0.27 mm in diameter) and has a continuous path through the entire length of the fabric. The patented method allows to increase the number of woven metallic conductor threads into carbon fabric, thanks to this, the total area of the conductor is 2.5 mm2. Copper conductor thread perfectly integrates with carbon fabric using textile processes.

technology of using infrared film Heat Plus Premium

The heating material is arranged in such a way that heat can spread both upward and downward. In order to not waste energy in vain, a layer of thermal insulation (a substrate) is laid under the material. In our store you can buy branded thermal insulation materials, which you can see in the catalog of goods.

#

the heating film Heat Plus Premium is used for the following purposes

  • Arrangement of a warm floor;
  • Equipment of additional heating systems in the premises;
  • Heated walls, loggias, balconies;
  • Systems of heating of agricultural buildings, devices for growing plants;
  • Organization of heating in pavilions, shops, kiosks, garages, etc .;
  • Ceiling heating device.;

installation of infrared film Heat Plus Premium

It is carried out in accordance with the instructions in the instructions that are attached to the material. For installation, the accompanying materials are used - thermal insulation substrate, protective coating, etc.

The thickness of all layers is different. It depends on the features of the finish material:

  • For parquet and laminate flooring - 0.45 cm.
  • Under the linoleum, carpet - 0.65 cm
  • Under the cement screed - 0,22 cm

materials required for installation of a floor heating system

when working with infrared film, safety measures should be followed

forbidden

  • To install at an air humidity above 70%, and also on wet surfaces
  • You can not use as a thermal insulation substrate, covered with foil of aluminum, metal
  • It is forbidden to mount an infrared film on the surface of metal, polystyrene foam, polystyrene, mineral wool, textiles
  • Make material kinks in the 0.5 m section by the value of the right angle or to the kink
  • It is impossible to impose an infrared film in two layers, to cross the cloths
  • Also, infrared film is prohibited from cutting in unauthorized places and placing heavy, sharp objects on it
  • still have questions?

    write to us, and we will reply

  • Kiev, Marii Kapnist str. 10a.

    044 502 03 56 (tel/fax)

    Wholesale department
    067 473 84 76

    Retail department
    099 722 89 24

    office@heatplus.ua